EMC
for
all environments
|
|
|
|
Arcom have designed
and tested the APC Pentium 4 product to meet the worst case conditions
for both emissions (EN55022 Class B) and immunity
(EN61000-6-2:2001). The product has also been tested emission and
immunity compliance with Railway Applications (EN50121-4:2000).
|
|
| CE |
| EU
89/336/EEC Electromagnetic Compatibility Directive, as amended
by 92/31/EEC
and 93/68/EEC
|
|
|
| EN
55022:1998 for Information Technology Equipment |
|

Optional breakout
panel

EMC gasketing

Seam welded
construction
|
Conducted Emissions:
Radiated Emissions: |
EN55022 Class B
EN55022 Class B |
|
|
| EN61000-6-2:2001
for Industrial Environment |
| Enclosure |
Related RF Immunity:
Electrostatic Discharge Immunity: |
EN61000-4-3
EN61000-4-2 |
|
|
| AC
Port |
Conducted Immunity, RF
common mode:
Fast Burst Transient Immunity:
Surge Immunity:
Voltage Dips and Interruption: |
EN61000-4-6
EN61000-4-4
EN61000-4-5
EN61000-4-11 |
|
|
| Signal Port |
Conducted Immunity, RF
common mode:
Fast Burst Transient Immunity: |
EN61000-4-6
EN61000-4-4 |
|
|
|
EU 72/23/EEC Low Voltage
Equipment Directive, as amended by 93/68/EEC.
The products comply with
the EU Low Voltage Equipment Directive by meeting the
following standard -
BS EN60950 : 1992 Safety of information technology equipment.
|
| |
|
Test Configuratons
|
|
|
Hardware
|
|
- Slot CPU
card
- 2.4GHz
Pentium 4 Processor
- 128MB
DDR SDRAM
- 40GB
Seagate HDD
- Sony Floppy
disk drive
- RW
CD DVD ROM drive
- PCIB40
- PCIB40 test
box
- 3 meter 50
way screened cable
|
 |
|
|
|
|
Software
|
|
- PCIB4EMC.EXE
test program
- MS-DOS O/S
|
A fully
detailed independent test report
is available for
inspection. |
|
| FCC
Verification: Part 15, Class A |
|
NOTE: This
equipment has been tested and found to comply with the
limits for a Class A, digital device, pursuant to part
15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful
interference when the equipment is operated in a
commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the
instruction manual, may cause harmful interference to
radio communications. Operation of this equipment in a
residential area is likely to cause harmful
interference in which case the user will be
required to correct the interference at his own
expense.
|
 |
|
|
|
|
|
|