HtMUX

8 to 56 channel HART to MODBUS Multiplexor

The HtMux is an intelligent serial multiplexer designed to convert between the HART and MODBUS protocols. Up to 64 HART channels may be driven from a single device, added in multiples of 8 channels at a time.  Both point to point and multidrop mode is supported, subject to a maximum of 512 transmitters per HtMux. Data is handed off via two RS232 serial ports using the MODBUS RTU protocol.  The HtMux is supplied as a 3U high cardframe suitable for mounting in a 19” rack, with all signal and power connections being made to the front.  RS232 MODBUS connections are available via two 9 pin ‘D’ type connectors. Build options are available for 110/220 Vac and 24Vdc. A further option exists for data to be handed off using the MODBUS protocol wrapped in TCP/IP frames on Ethernet.

Technical Documentation: Arcom provides on-line access to detailed technical documentation to help you select the best product for your application. Click here to download the manual for the HtMux and related products.
Specification
Architecture IEEE 1000
Processor/Clock Speed Single board computer (IEEE-1000)
Configuration 80486 @ 50MHz (SCIMX-T)
80486 @ 100MHz (SCPC)
Programming ACE
Size 3U Chassis
Mounting 19" Rack Mount
Memory 128Kbytes SRAM, 128Kbytes, 1Mbyte Flash, and 1Mbyte DRAM
Watchdog Yes
Serial Ports Two RS232, or optional RS485
Protocol HART Rev. 3, 4, & 5 (inputs)
MODBUS RTU (Host)
Power 110/220Vac or optional 24Vdc
Power Consumption For HtMux-8: 13 Watts
Add 5 Watts per additional 8 HART channels
Add 5.5 Watts for Ethernet (SETHER)

For HtMux-SER-8: 18 Watts
Add 10.5 Watts per additional 8 serial channels
Add 5.5 Watts for Ethernet (SETHER)

Operating Temperature -20 to +70ºC
Humidity 5 to 95% relative, non condensing
Input/Output 8 to 64 point-point devices, or up to 512 multidrop devices

 

More information


1 Year Product Warranty

Send this page to...

Operation
The HtMux is a HART fieldbus gateway device that interfaces a network of HART compatible devices to a MODBUS Host computer. System configuration features provide optimum setup for many different control schemes and system requirements.

The primary function of the HtMux is to poll Hart transmitters, and provide Real Time Process Variables in their original IEEE floating point format or in scaled integer format. A Host device will read the process variables from the HtMux using standard MODBUS Read commands.

Upon power up, the acquisition of the Process Variables (PV’s) from each of the HART devices connected to the HtMux is done in REAL TIME regardless of the number of channels configured. Each channel is fully HART conformant with regards to Primary and Secondary master network timing parameters.

Two MODBUS RTU serial communications ports are provided by the HtMux for interfacing to a MODBUS Host computer system. Both ports operate independently of each other. For instance, one port may be connected to the primary control host MODBUS device while the other one is connected to a maintenance computer system. For very high throughput applications, both MODBUS slave ports can be polled to double the effective data throughput. Alternatively, the Ethernet option is able to provide extremely high throughputs to host devices. Full multi-session support is available, allowing multiple hosts to connect to the Ethernet port at the same time.

The secondary function of the HtMux is to provide an interface to the non-real time or static database information  that may be of use in the control, data acquisition , or maintenance scheme. Through the use of data TEMPLATES, the MODBUS Host machine can have access to any definable data item in any of the transmitters in the system, including those which are only accessible using device specific commands.